Dedusting systems

The deduster sits inside an air circuit. Choose closed or open loop, and the dust collector that suits your material.

Closed-loop system (cyclone + inline filter)

Clean airDust-laden airPelletsPowerDPIHEPADPGSupplyCustomer supply380VAC/3PH/50Hz220VDeduster box220VAC/1PH/50HzVFD380VAC/3PH/50HzPellets inClean pellets out1234567891011

Tap the diagram to enlarge

Equipment

  1. 1Deduster
  2. 2Cyclone dust collector
  3. 3Inline filter
  4. 4VFD centrifugal blower
  5. 5HEPA filter
  6. 6Manual valve
  7. 7Dust bin
  8. 8Air-balance valve
  9. 9Support frame
  10. 10VFD cabinet
  11. 11Deduster junction box

Features

  • One blower serves both cleaning air and exhaust
  • Dust after cleaning down to ≤50 ppm
  • Suits raw material with dust below 500 ppm
  • Suits all gas-tight systems, especially nitrogen-blanketed lines
  • Suits toxic or hygiene-critical duties and moisture-sensitive materials
  • Modular, easy to maintain, low energy use

Closed-loop system (bag filter)

Clean airDust-laden airPelletsPowerNitrogenPDGLTMHEPADPGN₂N₂SupplyCustomer supply380VAC/3PH/50HzVFD380VAC/3PH/50Hz220VDeduster box220VAC/1PH/50HzPellets inClean pellets out1234567891011121314

Tap the diagram to enlarge

Equipment

  1. 1VFD centrifugal blower
  2. 2HEPA filter
  3. 3Duct before deduster
  4. 4Vent unit
  5. 5Deduster discharge air-inlet device
  6. 6Deduster
  7. 7N₂ make-up unit
  8. 8Return duct
  9. 9VFD cabinet
  10. 10Pulse-jet bag filter
  11. 11N₂ pulse cleaning unit
  12. 12Rotary valve
  13. 13Dust bin
  14. 14Deduster junction box

Features

  • One blower serves both cleaning air and exhaust
  • Dust after cleaning down to ≤50 ppm
  • For higher dust content in the raw material (below 2%) and large throughput, with automatic cleaning of the bags
  • Suits all gas-tight systems, especially nitrogen-blanketed lines
  • Suits toxic or hygiene-critical duties and moisture-sensitive materials
  • Modular, easy to maintain, low energy use

Open-loop system (cyclone + inline filter)

Clean airDust-laden airPelletsPowerDPGHEPADPGPellets inClean pellets outAmbient airDPIMLTSupplyCustomer supply380VAC/3PH/50HzVFD380VAC/3PH/50Hz220VDeduster box220VAC/1PH/50HzVFD380VAC/3PH/50HzExhaust1234567891011121314151617181818

Tap the diagram to enlarge

Equipment

  1. 1Fan inlet filter
  2. 2VFD supply blower
  3. 3HEPA filter
  4. 4Duct before deduster
  5. 5Deduster discharge air-inlet device
  6. 6Deduster
  7. 7Air-balance regulating device
  8. 8Duct after deduster
  9. 9Cyclone dust collector
  10. 10Manual valve
  11. 11Rotary valve
  12. 12Dust bin
  13. 13Inline filter
  14. 14Flexible connection
  15. 15Support frame
  16. 16VFD suction blower
  17. 17Level transmitter (LT)
  18. 18VFD cabinet / junction box

Features

  • Cleaning air and exhaust use two separate blowers
  • Dust after cleaning down to ≤50 ppm
  • Excellent for low dust content and smaller throughput
  • Airflow controlled by a damper or VFD on the supply blower outlet, or by the air-inlet on the suction side
  • Better airflow control when the dust collector is far from the deduster

Open-loop system (bag filter)

Clean airDust-laden airPelletsPowerDPGHEPADPGPellets inClean pellets outAmbient airPDGLTMAirSupplyCustomer supply380VAC/3PH/50HzVFD380VAC/3PH/50Hz220VDeduster box220VAC/1PH/50HzVFD380VAC3PH/50HzExhaust1234567891011121314151515

Tap the diagram to enlarge

Equipment

  1. 1Fan inlet filter
  2. 2VFD supply blower
  3. 3HEPA filter
  4. 4Duct before deduster
  5. 5Deduster discharge air-inlet device
  6. 6Deduster
  7. 7Air-balance regulating device
  8. 8Duct after deduster
  9. 9Pulse-jet bag filter
  10. 10Manual valve
  11. 11Rotary valve
  12. 12Dust bin
  13. 13Level transmitter (LT)
  14. 14VFD suction blower
  15. 15VFD cabinet / junction box

Features

  • Cleaning air and exhaust use two separate blowers
  • Dust after cleaning down to ≤50 ppm
  • Excellent for higher dust content and large throughput
  • Airflow controlled by a damper or VFD on the supply blower outlet, or by the air-inlet on the suction side
  • Better airflow control when the dust collector is far from the deduster

Illustrations are schematic. Detailed P&IDs are provided with a quotation.

Which one fits?

Closed loopOpen loop
BlowersOneTwo (supply + exhaust)
Best forGas-tight or nitrogen-blanketed lines, toxic or hygienic duties, moisture-sensitive materialsLong distance between deduster and dust collector; tighter airflow control
Cyclone + inline filterRaw material with low dust (below 500 ppm) and smaller throughput
Bag filterHigher dust content (below 2%) and large throughput, with automatic bag cleaning

Send us your material — we'll recommend the right model

Tell us the material, throughput and bulk density. We reply with a model recommendation and a suggested system layout.